Error Scanning / Deploying - GetMachineData Failed

$
0
0

Symptoms


When performing a scan or deployment an error occurs: GetMachineData failed.

 

Example of Error in ST.Protect.Native log located in the C:\ProgramData\LANDesk\Shavlik Protect\Logs folder :

 

2013-12-19T16:15:14.3055087Z 0330 E Deploy.cpp:1958 DeployMachine exception - class STCore::CInvalidOperationException at Deploy.cpp:1408: GetMachineData failed.

 

Cause       


This is caused by environmental factors, and is most commonly seen when scanning/deploying across a WAN.

 

Possible       


Because this issue is caused by environmental factors, the cause/solution will not always be the same. Here is a list of solutions that have been seen to help/fix the issue.

 

Note: These are suggestions based on previous customer feedback, and may or might not work for you. All suggestions are made without warranty; users assume all liability when modifying any network settings and/or devices.

 

  • Remote Procedure Call (RPC) Service Is Off
    • Verify that the target has the Remote Procedure CAll (RPC) service started.


  • Using a WAN Optimizer / Riverbed Device

    • In situations where a WAN Optimizer / Riverbed device are in use, these components have been seen to cause this issue.
  • Things to Try
    • Disable the device and try scanning/deploying.
    • Set the device to pass-through / by-pass mode.
    • Disable Latency Optimization in the device.
    • Ensure the device's firmware is up-to-date and restarted.
    • Reboot the device.

 

  • Target is Part of Domain
    • If the target is part of a domain, removing the machine from the Domain and re-adding it to the domain has been seen in some instances to correct the issue.


Related Article:HOW TO: Troubleshoot RPC Errors

 